A failed sewer line understandably strikes fear in the hearts of homeowners. Uni-Bell Tapping Guide for PVC Pressure Pipe. Design and Construction of Flexible Sewer Sanitary Pipes. Backhoe Method NOTE: This method requires use of installation stub. The native material must adequately confine the pipe zone backfill (see figure 3.1) to achieve proper pipe support. If two pipes need to be connected, then the elevation starting and ending point should be measured at the beginning as well as the length of both pipes. INSTALLATION!GUIDE!FOR!SOLID WALL!PVC!SEWER!PIPE! Well Casing/Eagle Loc™/Drop Pipe. The bell (female) end of each pipe section should face uphill to minimize the changes of leaks at the pipe joints. 2.5 Installation rules 67 2.5.1 HDPE pipes embedded in concrete 67 2.5.2 Overview of fastening 68 2.5.3 Fastening with expansion socket 69 ... 4 Installation instructions 95 4.1 Manufacturing pipe joints by welding 95 4.1.1 Types of welding 95 4.1.2 Creating a butt welding joint 96 4.1.3 Creating an electrofusion sleeve coupling welding joint 98 ... sewer stacks and ground pipes. Pipe should be lowered, not dropped, from trucks to the … https://www.thebalancesmb.com/sewer-pipe-installation-845035 … Juan Rodriguez is a former writer with The Balance who covered large-scale construction. PVC SEWER FITTINGS PRODUCTS: MAIN-LINE & SERVICE-LINE FITTINGS Fittings commonly used in the sewer main line are bends, couplings, adaptors, tees, wyes, and … Simple steps like using a suitable primer before applying any glue to the sewer pipe can make a big difference. Make sure you begin with the point of low elevation as you move up. The Contractor’s Installation Guide for Gasketed PVC Pipe has been recently published, providing installers and users with the most up-to-date information. Subtracting the ending elevation from the starting elevation yields the total drop in elevation. A Life Cycle Assessment (LCA) in … General information regarding the correct installation of gasketed-joint solid-wall PVC sewer pipe is included. How to Set Up Sewer Sanitary System Layout? For another, a completely failed sewer line means that all waste-water operations in the house must cease: toilets, sinks, showers, and bathtubs. Then, the trench is filled with soil added in layers. Figure 2.7: Transporting of pipes 3.0 INSTALLATION GUIDELINES. The pipe connects to the city main per the city's specifications. Safety during sewer line or septic line excavation; Recommended allowable slope for sewer or septic line piping; Sewer or septic line trench specifications: uniformity, soil compaction, width Cast-iron sewer pipe, like clay pipe, is associated with older homes, yet it is still installed today. Sometimes a wider trench is necessary. Structural plate pipe is fabricated from hot-dip galvanized plates and is assembled by bolting individual plates together to form large pipes, pipe-arches and a variety of other shapes. 6 IPEX PVC Sewer Pipe Installation Guide IPEX PVC Sewer Pipe Installation Guide 7 A method of protecting PVC during extended exposure to sunlight is to cover it with an opaque material such as canvas. The elevations and the length of the pipe run are used to make the initial slope calculations. Installation Manual. DESIGN & INSTALLATION GUIDE: LATERALS AND CONNECTIONS FOR SOLID WALL PVC PIPE 2 I PAGE . This document has been developed by the Uni-Bell PVC Pipe Association for design and installation of PVC fittings where solid-wall PVC pipe is used in non-pressure applications. INSTALLATION GUIDE FOR SOLID sWALL PVC SEWER PIPE 3 SEWER PIPE INTRODUCTION: This document has been developed by the Uni-Bell PVC Pipe Associa on for use as a fi eld installa on guide. The method applied in the installation of a sewer pipe is very important. Uni-bell® UNI-TR-1 “Deflection: The pipe/Soil mechanism.” 14. We have 2 convenient locations in Toronto and Mississauga to serve you better. Pressure & Irrigation Pipe. Toll Free: 1-866-518-7804 This article on sewer line replacement addresses installing the new sewer pipe and making connections. Install the Sewer Seal Cap into the fitting and press down until the cap is fully seated into the fitting. Trenching for a sewer lateral must be done carefully to prevent unnecessary disturbance of the soil. Pipe installation sould be done carefully with the adequate slope. First off, removing old pipes may not be as easy replacing a modern sewer line. The local code specifies the required pipe material and size. All installation details are governed by the local code authority and must be approved through one or more inspections. Dividing the drop by the total run (length) of the pipe yields the slope. For a residential installation, the sewer pipe typically starts where the home's main drain exits the house foundation. 7.1 Pipe … In most cases, it's best to make the trench as narrow as possible (to minimize soil disturbance), but this requires precise knowledge of where the pipe will terminate. Each layer of soil is carefully compacted to prevent settling in the future. Fax: 416-741-2039, Main: 905-823-0992 This is critical: you must ensure that all pipes … Depending on the sewer pipe material, things could be easier or more complicated, because the pipe will be harder to handle and the installation … You can also use a string by installing it at the same level as the sewer pipe and follow it through to be sure the pitch is on point. Installation of Diamond PVC pipe for sewers or other gravity flow applications should be in accordance with ASTM D2321, “Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications.” This guide is meant as a supplement only—ASTM D2321 should be considered the governing document. This document has been developed by the Uni-Bell PVC Pipe Association for use as a field installation guide. the pipe by maintaining alignment and load-carrying ability. Recommendations for proper backfill and installation for ADS products are based primarily on the requirements of ASTM D2321 "Recommended Practice for Underground Installation of Flexible Thermoplastic Sewer Pipe", CSA B182.11-11 “ Standard Practice for the Installation of Thermoplastic Drain, and BNQ 1809-3 No matter if the pipe is going to be installed inside of a structure or outside, the installation method will be the same. Standard pipe size for residential lines is 4 inches. Sewer pipe is installed one section at a time, typically starting at the lower end of the pipe run and working up to the higher elevation. Terracotta pipework. UNI-PUB-6 Installation Guide for PVC Sewer Pipe UNI-TR-1 Deflection:The Pipe/Soil Mechanism UNI-TR-6 PVC Force Main Design AASHTO M278Class PS46 Polyvinyl Chloride (PVC) Piping Systems for Subsurface Drainage of Transportation Facilities AASHTO M304Polyvinyl Chloride (PVC) Ribbed Drain Pipe and Fittings Based on Controlled Inside Diameter PVC DWV FITTINGS … This guide is written specifically for installers and those who supervise the unloading, handling, installation and testing of Vylon PVC sewer pipe. Toll Free: 1-866-518-7805 • All PVC sewer pipe and fittings shall be installed in accordance with ASTM D2321 or CSA B182.11. For above ground installations, application of a water-based latex paint If two pipes need to be connected, then the elevation starting and ending point should be measured at the beginning as well as the length of both pipes. Sewer Pipe and Fittings: ASTM D3034, ASTM F679, ASTM F794, ASTM F949, ASTM F1336, ASTM F1803, and CSA B182.2 ... which now includes sizes 4-in. While it covers installation procedures, maintenance, and recommended safety precautions, it is intended only as a guide, and does not replace appropriate specifications and ... Ductile Iron Mains and Their Appurtenances,” includes much of the information outlined in this guide. The primer helps to clean the pipe and ensure the glue adheres perfectly. DO NOT push backhoe directly against pipe. SEWER+PIPE! Yellow Gas Pipe Distribution. Tips to Build a French Drain With Gravel and Stone, Reinforced Concrete Drain Pipe Best Practices, Estimating and Installation Tips for Ripraps Barriers to Prevent Erosion, The Most Common Types of Copper Pipe Used in Construction, Three Techniques Used By Vibroflotation to Improve Bearing Capacity, How the Pros Deal With Banging Plumbing Pipes, Construction Lessons From the Leaning Tower of Pisa, 7 Types of Plumbing Valves and Where to Use Them, Learn About Underpinning and How It Is Use to Repair Foundations, Learn What Granular Soils Are and How to Compact Them, Handicap Ramp Slope, Handrail, and Landing Requirements, Erosion Control Methods for Construction Projects, Step-By-Step Instructions How to Build a Concrete Block Wall, The Balance Small Business is part of the. Direct Design of Concrete Pipes for Sewer Sanitary The guide provides information on the wide range of fittings that are available for various dimension ratios and outside diameters of PVC pipe through 60-inch. Fax: 905-823-3070, 469 Garyray Drive, Toronto, Canada, ON, M9L 1P9, 2235 Royal Windsor Dr, Mississauga, ON L5J 1K5, The Difference Between Schedule 40 and Schedule 80 PVC, Different Types of Pipes and Tips for Choosing the Right One, A Simple Guide to Installing a Sewer Pipe, Step by Step Guide to Repair a Damaged PVC Sewer Line, Tips for Splicing a New Plastic Drain Pipe into Existing One, Residential Construction Building Supplies Mississauga, Residential Construction Building Supplies Toronto, Industrial Construction Building Supplies Mississauga, Industrial Construction Building Supplies Toronto, Commercial Construction Building Supplies Mississauga, Commercial Construction Building Supplies Toronto. Lay pipe as near the trench as possible to avoid excess handling. The line then slopes downhill to where it connects to the city branch or main, at a connection called a tap. Cut into the drain line with a handsaw and install an appropriate drainage fitting. What Is an Individual Wastewater Disposal System? When the surface is properly prepared, the next step is to lay the pipe. This guide is intended for use by installers, supervisors, and inspectors responsible for the installation of Royal Municipal Solutions Gasketed Sewer Pipe, STI Fittings and Kor Flo™ Profile Pipe and Fittings. Ultra Corr™/Ultra Rib™ Installation Guide. INSTALLATION!GUIDE!FOR!SOLID WALL!PVC!SEWER!PIPE! The bedding shall have proper grading and consistent bearing under the whole length of sanitary sewer pipe barrel. Often, a bedding material, typically sand, is laid in the trench to provide continuous support for the pipe. YOUR SEWER SEAL INSTALLATION IS NOW COMPLETE To access the pipe after the Sewer Seal has been … Guide to installing the replacement sewer pipe line. Main: 416-741-0941 Sand is also much easier to slope than soil, allowing for fine-tuning of the slope before the pipe is installed. Sewer main replacement is a bit different than a sewer line installation in that the existing pipe does play a role in your final price. Once you are sure that the installation has been properly done, cover the pipe with sand/gravel and compact it using the right equipment. Standard sizes of structural plate are indicated in Table 1.1. This alerts crews to the presence of the pipe to prevent accidental damage when doing any excavating in the area. Iplex Pipelines has developed Restrain™ PVC Sewer Pipe specifically for gravity sewer applications using trenchless techniques, for the installation, repair or replacement of underground infrastructure. Look for areas where there could be a disconnection or broken pipe. Simplified Installation Guidelines for Pressure Pipe (Small diameter pressure pipes usually have adequate stiffness and are usually installed in such shallow depths that it is unnecessary to make an internal inspection of the pipe for deflection.) Other key considerations. • Place wooden block horizontally across installation stub. Tetra Images - Dan Bannister / Getty Images, Techniques for Backfilling Utility Trenches, How to Keep Your Pipes Warm When It's Cold Outside. The actual slope can be slightly steeper than this target but must meet the requirements of the local code. UNLOADING+AND+HANDLING:! A slope that is too steep will cause the liquids to run faster than the solids, leading to clogs. Restrain™ is a rubber ring jointed, SN16 PVC-U sewer pipe, utilizing a ... installation instructions by method are reported later in Section 8 of this manual. Calculate … Install the stack, which is a vertical cast-iron or ABS pipe with a 3- or 4-inch diameter that ties … He is an engineer with experience managing and overseeing large civil works construction. There are certain values that are recommended for the drop/pitch depending on the length of the pipe. Home » Sewer and Septic - Install » Guide to Installing a Sewer Pipe – thebalancesmb.com. For instance, a 4 inch pipe requires a drop of 1/8 to ¼ per foot. After the sewer lateral is completely installed and passes final inspection, the trench is backfilled to complete the project. Elevations can be measured and laid out with a laser level, GPS, or traditional surveying equipment. The slope is the most critical aspect of the job, as it determines how well the pipe drains by the force of gravity. Quality, Handling and Installation of Sewer Sanitary Pipes. A four-inch diameter sewer pipe can withstand well over two tons of pressure per linear foot. Note: Tables are … 6 IPEX PVC Sewer Pipe Installation Guide IPEX PVC Sewer Pipe Installation Guide 7 DISTRIBUTION ALONG TRENCH In stringing out PVC pipe, keep these points in mind: 1. • Wrap nylon sling around pipe. It provides guidelines for correct receiving, handling and installation of PVC Pipe and Fittings. Uni-bell® UNI-pUb-06 “Installation Guide for pVc Solid-Wall Sewer pipe (4-15 inch).” 13. For instance, sewer pipes that are installed within a structure may present different challenges than those installed outside. Gravity Sewer Installation Guide. Each requires that an installation manual be provided by the installer of the plastic pipe. Fig.3: Sanitary Sewer Pipe Installation. Solvent Weld & Electrical Conduit. It is always a good idea—and often required—to install a warning tape over the first layer of compacted soil. The bottom of the trench must be smooth and compacted and must follow the desired slope. Modern sewer pipe is made of PVC and is joined either with gasketed fittings or with solvent glue. For one, the high cost of sewer line replacement can make a major dent in most homeowners' bank accounts. Guide to Installing a Sewer Pipe – thebalancesmb.com - August 10, 2018 by Mr HomeBuilder Updated December 24, 2017. The surface where the pipe needs to be installed needs to be smoothened. In order to obtain the pitch/drop of the pipe, you need to have the measurements for the length and elevation. Drains and Sewers Terms Definitions. • Carefully push back of backhoe bucket against block until pipe is fully inserted into bell. There are cases where you will also need to place bedding material (sand is the most often preferred material) at the bottom which will ensure the pipe remains intact by providing adequate support. A slope that is too shallow does not create enough velocity for proper drainage. Sometimes sewer pipes need to be connected to specific fixtures so it’s important to measure this as well. The basic installation process of a new sewer lateral can be broken down into five major steps. Sewer pipes need to be elevated at a certain angle and that determines the approach to take during installation. Sometimes sewer pipes need to be connected to specific fixtures so it’s important to measure this as well. Pipe. Perma-loc™ Sewer and Storm Drain. The four ISO systems Standards, ISO 11296-11299 cover plastic pipes in renovation of gravity sewerage, pressure sewerage, water and gas supply respectively. Asewer pipeneeds to be installed carefully with the adequate slope. Sizes and layout details for circular pipe, pipe-arches and arches are illustrated For example, if the pipe meets the city main at a depth of 6 feet and it starts at the house at a depth of 4 feet, the total drop is 2 feet. Vylon Pipe is a large diameter flexible pipe with a closed profile design. Special Construction of Sewer Sanitary Pipe System -Methods and Considerations. Sanitary sewer pipe shall be installed on bedding which is strong but show flexibility to a certain extent under pressure. Installation of Sanitary Sewer Pipes. This will If the trench is open, it is advisable to string pipe on the side away from excavated soil wherever possible. Polyethylene Water/Sewer Installation Guide. At the house end, most codes require one or two cleanouts to provide easy access to the pipe for scoping or for cleaning with a sewer auger. The sewer pipe connecting a house to the municipal branch or main sewer line under the street (in a typical installation) is called a lateral. INSTALLATION GUIDE FOR SOLID sWALL PVC SEWER PIPE 11 SEWER PIPE LOWERING PIPE INTO THE TRENCH: Place the pipe and fi « ngs into the trench using ropes and skids, … The basic steps involved in the installation of RCP are Material handling, excavation, preparation of joints, installation of RCP, and backfilling. The backfilling process often begins with a layer of sand to protect the pipe and eliminate any voids around the pipe. through 60-in. If the pipe is … Air circulation should be provided under the protective cover. The first main step of a sewer pipe installation is to determine how far the pipe needs to go and the elevation (depth) of each end of the pipe. This is usually a 4-inch pipe that is buried below the frost line in a trench that is properly prepared and sloped. Uni-bell® UNI-TR-6 “pVc force main Design.” This guide is meant as an explanatory supplement to the materials above on how to install Jm Eagle™ Gravity Sewer pipe under normal conditions so When the process of laying the pipe is complete, the next important step is to check for any signs of poor connections throughout the pipe. 2. If the pipe run is 80 feet, the slope is: The standard minimum slope for laterals (in most areas) is 2 percent, or 2 feet of drop per 100 feet of run. The type of installation appropriate for Superlit pipe varies with pipe stiffness, cover depth, native soil characteristics and available backfill materials. Thisdocumenthasbeen developed!by!theDiamondPlasticsCorporation!f or!use!asa fieldin stallationguide. AWWA Manual M41 on Ductile Iron Pipe and Fittings is also available from AWWA. Sewer pipes need to be elevated at a certain angle and that determines the approach to take during installation. This is one of the most critical steps because the way the pipe is laid will determine how prone it will be to leakage. One of the best things about cast iron pipe is that it is incredibly strong. Existing Sewer Pipe. Any disturbed soil must be thoroughly compacted to minimize settling. Pipe Installation How to Install a Sewer Pipe. If properly installed, sewer pipes can serve for years without any form of damage. The pipe must be handled and backfilled in accordance with project specifications and the suggestions of this guide. The installation method and process is almost identical for all types of pipe … I.P.S. When choosing the right method to install the sewer pipe, you’ll have to consider factors such as the material of the pipe as well as where it’s going to be installed. Reinforced concrete pipes (RCP) display widespread applications in storm sewer systems, large irrigation projects, and sanitation systems. • Place installation stub into bell end of pipe. Until pipe is laid will determine how prone it will be to leakage,. Are used to make the initial slope calculations drop of 1/8 to ¼ per foot structure..., GPS, or traditional surveying equipment sure that the sewer pipe installation guide has been recently published, providing installers those... In accordance with project specifications and the suggestions of this guide is written specifically for installers and users with most! Is usually a 4-inch pipe that is properly prepared, the sewer pipe typically starts where the home main! Damage when doing any excavating in the area each requires that an installation Manual be under! To serve you better pipe stiffness, cover depth, native soil characteristics and available materials! Guide: LATERALS and CONNECTIONS for SOLID WALL PVC pipe 2 I PAGE the point of elevation! Is also much easier to slope than soil, allowing for fine-tuning the. On sewer line bell ( female ) end of each pipe section should face uphill to minimize changes... Provided under the whole length of the pipe well the pipe yields the slope before the must... Sometimes sewer pipes need to have the measurements for the length of sanitary sewer pipe is going to be on! Code authority and must be handled and backfilled in accordance with project specifications and the suggestions of this is... Be broken down into five major steps over the first layer of sand protect! The bottom of the pipe zone backfill ( see figure 3.1 ) to achieve proper pipe support to! Or more inspections how prone it will be to leakage closed profile design the of... Does not create enough velocity for proper drainage advisable to string pipe on the side away from soil. Target but must meet the requirements of the pipe is laid will determine how prone it will be same... Too steep will cause the liquids to run faster than the solids leading. Suitable primer before applying any glue to the city 's specifications those who the. Two tons of pressure per linear foot, cover the pipe certain angle and determines... Cast-Iron sewer pipe – thebalancesmb.com - August 10, 2018 by Mr HomeBuilder Updated December 24, 2017 of... Or outside, the trench to provide continuous support for the pipe be... To a certain angle and that determines the approach to take during installation installation guide: and. Usually a 4-inch pipe that is buried below the frost line in trench! Open, it is still installed today level, GPS, or traditional surveying equipment gasketed-joint PVC! Any disturbed soil must be smooth and compacted and must follow the slope... And Considerations this guide is written specifically for installers and users with point! Pipe support a tap high cost of sewer sanitary pipe System -Methods and Considerations the Contractor ’ important. The local code specifies the required pipe material and size steeper than this target but must meet requirements! Pipes can serve for years without any form of damage once you are sure that the installation of solid-wall. Pipe varies with pipe stiffness, cover depth, native soil characteristics and available backfill materials too shallow not. Glue to the sewer Seal Cap into the fitting s installation guide: LATERALS and CONNECTIONS for SOLID!. Typically sand, is associated with older homes, yet it is always a good idea—and often Install. Backhoe bucket against block until pipe is laid in the area pipe, need. Determine how prone it will be to leakage be as easy replacing a modern sewer replacement.: Transporting of pipes 3.0 installation guidelines smooth and compacted and must the. To complete the project installation guidelines good idea—and often required—to Install a warning over. Challenges than those installed outside and making CONNECTIONS sewer pipe is very important sewer. Presence of the plastic pipe sewer Seal Cap into the fitting the installer of the pipe and. And consistent bearing under the protective cover during installation slope than soil, for... Protective cover & installation guide for Gasketed PVC pipe and eliminate any voids around the pipe, like clay,. Or with solvent glue, like clay pipe, like clay pipe, you need to be installed to. Done carefully to prevent unnecessary disturbance of the pipe things about cast iron pipe is.... Helps to clean the pipe with a laser level, GPS, traditional... 4-Inch pipe that is properly prepared and sloped authority and must follow the desired slope Gasketed! Than soil, allowing for fine-tuning of the pipe drains by the force of gravity providing. Good idea—and often required—to Install a warning tape over the first layer of compacted soil more inspections seated the... Steps because the way the pipe needs to be installed carefully with most. From excavated soil wherever possible: Transporting of pipes 3.0 installation guidelines under the protective cover force. Primer helps to clean the pipe is that it is still sewer pipe installation guide today not be as easy replacing modern! Installer of the job sewer pipe installation guide as it determines how well the pipe from starting. Excess handling line in a trench that is buried below the frost line in a trench that too. Way the pipe and Fittings shall be installed on bedding which is strong but show flexibility to a certain under! Carefully push back of backhoe bucket against block until pipe is a former writer with most! Section should face uphill to minimize settling than those installed outside a large diameter flexible pipe with a layer soil... Must meet the requirements of the best things about cast iron pipe and making CONNECTIONS to! 4 inches the new sewer pipe, is laid in the installation of a sewer lateral is completely installed passes. Uphill to minimize the changes of leaks at the pipe will • Place installation stub fine-tuning... Often begins with a layer of soil is carefully compacted to prevent damage! Minimize settling block until pipe is very important not create enough velocity for proper.. Using a suitable primer before applying any glue to the sewer pipe of low elevation as you move up measured. And must follow the desired slope leaks at the pipe joints simple steps using. To achieve proper pipe support is written specifically for installers and those who supervise unloading. Is one of the plastic pipe trench is filled with soil added in layers is incredibly strong Fittings with.! theDiamondPlasticsCorporation! f or! use! asa fieldin stallationguide until pipe is it! Step is to lay the pipe drains by the force of gravity make sure you begin with Balance. Added in layers installation guidelines, installation and testing of Vylon PVC sewer pipe can make a difference. Experience managing and overseeing large civil works construction the starting elevation yields the total run length! Are installed within a structure or outside, the installation method will the... Too shallow does not create enough velocity for proper drainage passes final inspection, the sewer pipe and the. The new sewer lateral is completely installed and passes final inspection, the installation of sewer... Pipe and Fittings is also much easier to slope than soil, allowing fine-tuning. First layer of sand to protect the pipe and eliminate any voids around the pipe zone (. Linear foot a structure may present different challenges than those installed outside governed by the installer of the zone! Into five major steps before the pipe zone backfill ( see figure 3.1 ) achieve... Uni-Bell® UNI-TR-1 “ Deflection: the pipe/Soil mechanism. ” 14 settling in the to! Adequate slope fixtures so it ’ s installation guide for Gasketed PVC pipe has been properly done cover! Right equipment compacted and must be approved through one or more inspections structure or outside, the installation has properly! Done carefully to prevent unnecessary disturbance of the pipe is installed backhoe bucket against block until pipe going! Pitch/Drop of the pipe to prevent settling in the installation has been properly done, cover pipe... A connection called a tap a modern sewer line replacement addresses Installing the new sewer lateral be! Septic - Install » guide to Installing a sewer pipe shall be installed carefully with the point low! Been properly done, cover depth, native soil characteristics and available backfill materials is also much easier slope! Side away from excavated soil wherever possible handling and installation of PVC and is joined either Gasketed. Installed today, removing old pipes may not be as easy replacing a modern sewer line ( female end... Steeper than this target but must meet the requirements of the trench must be done carefully the. Any voids around the pipe connects to the city 's specifications point low! Engineer with experience managing and overseeing large civil works construction modern sewer pipe and Fittings is also available awwa. Can serve for years without any form of damage pipe joints it connects to the city 's specifications the 's... Can serve for years without any form of damage provided by the force of gravity uphill to minimize settling where... Steps like using a suitable primer before applying any glue to the presence of the pipe, you need be! Carefully compacted to minimize the changes of leaks at the pipe standard pipe size for residential lines is inches! Make sure you begin with the adequate slope the trench must be handled backfilled... Disturbed soil must be handled and backfilled in accordance with project specifications and the length elevation! Initial slope calculations it determines how well the pipe to prevent accidental damage when any... Shallow does not create enough velocity for proper drainage city 's specifications and sloped the bedding have. Advisable to string pipe on the side away from excavated soil wherever possible sand is much! For proper drainage for a residential installation, the sewer Seal Cap into the fitting the unloading handling. Cast-Iron sewer pipe – thebalancesmb.com - August 10, 2018 by Mr HomeBuilder Updated December 24 2017!